ComputeDomains

How compute-domain.nvidia.com provisions ephemeral Multi-Node NVLink fabrics via IMEX.

A ComputeDomain is a custom resource that sets up a group of nodes to run a multi-node workload using NVLink fabric. It is used to enable GPU memory sharing across nodes in hardware that supports Multi-Node NVLink (MNNVL), such as GB200 NVL72 or H100 NVLink configurations.


IMEX lifecycle modes

The resources.computeDomains.imex.mode Helm value determines who manages the nvidia-imex daemon lifecycle.

ModeLifecycle
driverManagedBy default, the DRA Driver creates one nvidia-imex DaemonSet for each ComputeDomain and tracks daemon readiness through ComputeDomainClique resources.
hostManagedYou run nvidia-imex as a host service with a ready command socket, and the DRA Driver does not create daemon DaemonSets or daemon claims; this mode requires the HostManagedIMEXDaemon feature gate.

How driver-managed mode works

Creating a ComputeDomain in the default driverManaged mode triggers the following sequence:

  1. The compute-domain-controller watches for new ComputeDomain resources and creates a per-domain DaemonSet.
  2. Each daemon pod in that DaemonSet runs nvidia-imex, which manages the NVLink fabric connection on its node.
  3. Each daemon publishes its IP address, clique membership, and readiness via a ComputeDomainClique CR in the driver namespace.
  4. The compute-domain-controller also creates a ResourceClaimTemplate per channel, making IMEX channels available for workload pods to claim.
  5. When a workload pod claims a channel, the compute-domain-kubelet-plugin injects one or more selected IMEX channel devices (/dev/nvidia-caps-imex-channels/channelN) into the container.

For the full sequence diagram, see Architecture › Driver-managed ComputeDomain flow.

How host-managed mode works

Creating a ComputeDomain in hostManaged mode uses an existing host nvidia-imex service:

  1. You run nvidia-imex on each participating GPU node and expose its command socket.
  2. The compute-domain-controller creates the workload ResourceClaimTemplate.
  3. When a workload pod claims a channel, the compute-domain-kubelet-plugin queries the host daemon through the daemon’s command socket and requires a READY response. If the daemon is unavailable or not ready, claim preparation fails and is retried.
  4. After the readiness check succeeds, the plugin injects channel 0 (/dev/nvidia-caps-imex-channels/channel0) into the workload container.
  5. Deleting the ComputeDomain removes the workload claim template, but it does not stop or reconfigure the host service.

Host-managed mode currently supports domain isolation only. All ComputeDomains that use the same host IMEX domain share channel 0. Because this mode has no per-ComputeDomain daemon pods, the controller disables its IMEXDaemonsWithDNSNames and ComputeDomainCliques behaviors and does not create ComputeDomainClique objects. A Ready ComputeDomain therefore does not report the health of the host service.

For service and socket configuration, see Host-managed IMEX.